INSTRUCTION MANUAL - EUROPEAN VERSION 135369 06.03.08 63
SC22-3 Safety Controller Operating Instructions OBI
6.3.2 Confirm Configuration
Before configuration can be used in a Safeguarding application, it
must be confirmed. To Confirm Configuration:
1) Select Confirm Configuration and
press OK. Screen 129 is shown.
The safety-critical configurations for the In-
puts, Safety Outputs and system settings
must now be reviewed. An unchecked box
in the Confirm Configuration menu indi-
cates the safety-critical settings have not
yet been confirmed. Screen 129 refers.
6.3.2.1 Confirm Configuration of Inputs
From Screen 129 Confirm Configuration menu, select Inputs and
press OK. Screen 130 is shown.
1) At screen 130, Confirm by selecting
e.g. E-Stop ES01, then press OK.
Screen 131 is shown.
The next series of menus lists the safety-critical configurations for
this input.
2) Review safety-critical configurations for each setting of this input
at following screens, screen 131, screen 132, screen 133,
screen 134 and screen 135 and then press OK:
.
3) Repeat confirmation process for each of the Inputs.
When all Inputs have been confirmed,
Screen 136 is shown.
4) To continue Confirm Configuration,
select <Done> and press OK.
6.3.2.2 Confirm Configuration of Outputs
1) From Screen 129 select Confirm Configuration menu, and press
OK. Screen 137 is shown.
2) At screen 137, sel
e
ct Safety Outputs,
then press OK. Screen 138 is shown.
3) Confirm Safety Output SO1’s configu-
ration by selecting SO1 and then
press OK.
The next series of menus lists the safety-
critical configurations for SO1.
4) Review safety-critical configurations for S01 of this Safety Out-
put at following screens, screen 139, screen 140 and
screen 141 then press OK.
5) Repeat confirmation process for SO2 and SO3.
When all Safety Outputs have been con-
firmed, Screen 136 is shown.
6) To continue Confirm Configuration,
select <Done> and press OK.
6.3.2.3 Confirm Configuration of System Settings
1) From Screen 129 select Confirm Configuration menu, and press
OK. Screen 143 is shown.
2) At screen 143, select System Settings,
then press OK. Screen 138 is shown.
The next series of menus lists the safety-
critical System Settings.
3) Review safety-critical configurations
for System Settings at following screens, screen 144,
screen 145 and screen 146 then press OK.
Screen 128
Screen 129
Screen 130
Screen 131
Screen 132
Screen 133
Screen 134
Screen 135
Screen 136
Screen 137
Screen 138
Screen 139
Screen 140
Screen 141
Screen 142
Screen 143
Screen 144
Screen 145
Screen 146
Page view 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 143 144

Comments to this Manuals

No comments