Product Select
The Hardware Input option signals the sensor to run the product option currently selected by the
Product and Product Select input lines (not necessarily what is shown in the drop-down list on the
tab). With this option selected, then, the Product Change and Product Select input will change the
inspection when signaled to do so.
The Software Override option is typically used for troubleshooting a specific inspection and it
signals the sensor that you will manually select an inspection to run. The inspection displayed in
the field next to Software Override will be the inspection that runs.
Enter the number of seconds failed images should be displayed on the
optional NTSC video monitor. The default is 1 second.
Failed Image Hold
Enter the number of milliseconds to delay the camera before it takes a
picture after the sensor receives a valid trigger. The default is 0
milliseconds.
Trigger Delay Adjust
Note: Using the Trigger Delay when a part is triggered too early may be easier than moving the
sensor.
Select Tab