Banner PresencePLUS P4 EDGE 1.3 Series User Manual Page 196

  • Download
  • Add to my manuals
  • Print
  • Page
    / 258
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 195
CommentsOptional
Qualifiers
Required
Qualifiers
Support
Actions
Object or
Activity
Identifier
System
Object,
Component,
or Activity
Retrieve the
system error
count
NoneNoneGETSYSERRCNTSystem Error
Count
Retrieve the
missed trigger
count
NoneNoneGETMISSTRIGCNTMissed Trigger
Count
Retrieve the
cached status
of the I/O line
NoneI/O line id,
numeric, either
1 through 4 or 1
through 6
GETIOSTSI/O Line Status
Retrieve the
gain
NoneGETGAINGain
Set the gainNonePositive IntegerSETGAINGain
Retrieve the
camera
exposure
NoneGETEXPOSUREExposure
Get the camera
exposure
NonePositive NumberSETEXPOSUREExposure
Enables frame
number as
NoneENABLESETFRAMETAGFrame Number
Tag
command
acceptance
indicator
Disables frame
number as
NoneDISABLESETFRAMETAGFrame Number
Tag
command
acceptance
indicator
Retrieve the
status of the
NoneNoneGETFRAMETAGFrame Number
Tag
frame tag
indicator
8.7.2 RCC Return Values
RCC return values are numeric, and are listed below:
P/N 000000Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
196
7/2009Communication Tool Setup
Page view 195
1 2 ... 191 192 193 194 195 196 197 198 199 200 201 ... 257 258

Comments to this Manuals

No comments