precedes the Measure tool in the order of operation (that is, if the Location tool is to the left of the Measure
tool in the Navigation/Results window), then the x- and ycomponent values and the angle of the line change
as rotation occurs.
Relative
For the Measurement type to be set to Relative, a Location-type tool must precede the Measure tool in the
order of operation. When the user selects the Relative type, the window indicates to what Locate tool the
measurement is relative.
The coordinate system of the Measure tool changes based on the rotation information the Location-type tool
provides. The x- and y-components and the angle of the measurement remain constant even if the part rotates
in the camera’s FOV. The relative Measure tool is relative to the rotation-enabled Locate tool. The part has
rotated, but the x- and y-distances and the angle of the line are largely unaffected.