Banner RP-QM90 Rope Pull Switch User Manual

Browse online or download User Manual for Special machinery Banner RP-QM90 Rope Pull Switch. Banner RP-QM90 Rope Pull Switch User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Datasheet
Positive-opening safety contacts (IEC 60947-5-1), not dependent
upon springs
Contacts latch open when rope is pulled; requires manual reset
Heavy-duty die cast metal housing, rated IP65, suitable for demanding
industrial environments
Rope spans up to 100 m (330 ft), with the switch mounted in the center
of the span
Both safety contacts are closed with normal rope tension, and open when
rope is pulled or if rope breaks (or if tension is reduced from normal
amount)
Extra contacts for monitoring or to provide dual-channel input to a safety
module
Switch actuator position clearly indicates when rope has proper tension
for operation
Long life, switch rated at 1 million mechanical operations, minimum
Protective Earth Terminal (IEC 60947-1)
Model
Max. Overall
Rope Length
Run Position Cable Pulled
(either side)
Cable Break
(either side)
Switching Diagram
RP-QM90F-100L 100 m (330 ft)
23 24
11 12
11 12
23 24
23 24
11 12
11 12
23 24
23 24
11 12
11 12
23 24
11 - 12
23 - 24
40°
40°
30°
30°
0
Lock
70N
70N
Lock
Lever
11 - 12
23 - 24
RightLeft
Contacts: Open Closed
NOTE:
This symbol for a positive-opening safety contact (IEC 60947-5-1) is used in the switching
diagram to identify the point in actuator travel where the normally-closed safety contact is fully open.
Important... Read This First
Regarding the Use of Rope Pull Switches. In the United States, the functions that Banner rope pull switches are
intended to perform are regulated by the Occupational Safety and Health Administration (OSHA). Whether or not any
particular rope pull switch installation meets all applicable OSHA requirements depends upon factors that are beyond the
control of Banner Engineering Corp. These factors include the details of how the switches are applied, installed, wired,
operated, and maintained.
Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance
instructions in this document. Direct any questions regarding the use or installation of rope pull switches to the factory
applications department.
RP-QM90 Series Rope Pull Switches
P/N 62086 Rev. D 4 February 2014
62086
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Datasheet

Datasheet• Positive-opening safety contacts (IEC 60947-5-1), not dependentupon springs• Contacts latch open when rope is pulled; requires manual reset

Page 2 - Overview

Banner Engineering Corp. recommends that rope pull switches be applied according to the guidelines set forth in thestandards listed below. In addition

Page 3 - Mechanical Installation

Figure 1. Run Position: Proper Rope TensionFigure 2. Rope Pulled: Contact Pairs 11-12 OpenFigure 3. Rope Break or Slack: Contact Pairs 11-12 OpenMecha

Page 4 - Electrical Installation

All hardware is supplied by the user. The switch mounting holes are on a standard limit switch mounting pattern of 30 x 60millimeters, and accept M5 (

Page 5 - Specifications

Maintenance/CheckoutAt switch installation or replacement and at machine set up, a Designated Person1 must test each switch for propermachine shutdown

Page 6 - Accessories

Dimensions11 1223 2411 1223 24206 mm(8.10") 10.0 mm(0.39")58 mm(2.33")24.5 mm(0.97")125 mm(4.90")137 mm(5.40")186.0 mm(7

Page 7 - Pull ring

One conduit adapter is supplied with each switch.Components for the Wire Rope Assembly112311 1223 24Pull ringto resetThimble ClampPulleyTensioning Spr

Page 8

Model Quantity Description Tensioning SpringRPA-S1-1 1 Tensioning spring #1Model Quantity Description Tensioning SpringRPA-S2-1 1 Tensioning spring #2