DatasheetFigure 1. Standard ModelFigure 2. Teflon-Protected Model• Fast, easy-to-use TEACH-Mode programming; no potentiometeradjustments• SPDT electro
5-Pin Micro-Style Cordsets with ShieldModel Length Style Dimensions Pinout (Female)MQVR3S-506 1.83 m (6 ft)Straight 42 Typ.ø 14.51/2-20 UNF-28 32514
SAFQT50U • PVC mounting flange mounts to the front of a QT50U sensor (notfor use with chemical-resistant models).• Adapts sensor to thread into standa
Principles of OperationUltrasonic sensors emit one or multiple pulses of ultrasonic energy, which travel through the air at the speed of sound. Aporti
Action ResultNo further action required; sensor stores selection and remains inRUN mode.2. Enable or disable the temperature compensation.Action Resul
Sensor ProgrammingTwo TEACH methods may be used to program the sensor, using the TEACH button:• Teach individual minimum and maximum limits.• Use the
Action ResultPosition the target for the second limit.Click the TEACH button. The sensor stores both limits and Output LED turns solid amber.The senso
Action ResultPosition the target at the desired midpoint for the sensingwindow.Click the TEACH button. Output LED changes to flashing red3. Teach the
SpecificationsSensing Range200 mm to 8 m (8 inches to 26 feet)Supply VoltageUniversal Voltage: 85 to 264 V ac, 50/60 Hz / 48 to 250 V dc (1.5watts max
DimensionsCabled Models 5-pin Mini-style Models5-pin Euro-styleModels67.4 mm[2.66”]38.1 mm[1.5”]18 mm[0.71”]66 mm[2.6”]84.2 mm[3.32”]33 mm[1.3”]Temper
WiringCabled Models QD ModelsNormally Open/Pump-In Normally Open/Pump-In Loadbkyebnbuwh85-264V ac, 50/60 Hz 48-250V dc**shield*Output Current 8A Max.