Banner Q08 Series User Manual Page 1

Browse online or download User Manual for Sensors Banner Q08 Series. Banner Q08 Series User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Low-profile infrared sensors in rugged metal housings
Miniature right-angle dc photoelectric sensors in rugged die-cast metal housings
Ultra-thin; only 8 mm (0.3") deep
Totally self-contained; 10 to 30V dc operation
Easy mechanical alignment
Circuitry is completely sealed and epoxy-encapsulated; rated IP67 and NEMA 6
Select models with NPN (sinking) or PNP (sourcing) output
Select light operate or dark operate models
3-wire hookup; output load capacity to 150 milliamps
LED indicators for Power ON and Output ON; Output indicator may be used for
alignment
Infrared, 880 nm
Range of 2.5 mm to 61 mm (0.1" to 2.4")
DIFFUSE
Models Cable
Output
Type
Excess Gain Beam Pattern
NO5-Q08-AN7
NO5-Q08-AN7V1131
2 m (6.5 ft)
3-Pin Pico QD
NPN/LO
1
10
100
10 mm
0.4 in
100 mm
4.0 in
1000 mm
40 in
1 mm
0.04 in
1000
E
X
C
E
S
S
G
A
I
N
DISTANCE
Q08
Diffuse Mode
52.5 mm
2.5 in
40.0 mm
2.0 in
37.5 mm
1.5 in
25.0 mm
1.0 in
12.5 mm
0.5 in
0
0
2.5 mm
5.0 mm
7.5 mm
2.5 mm
5.0 mm
7.5 mm
0
.1 in
.2 in
.3 in
.1 in
.2 in
.3 in
Q08
Diffuse Mode
DISTANCE
NO5-Q08-RN7
NO5-Q08-RN7V1131
2 m (6.5 ft)
3-Pin Pico QD
NPN/DO
NO5-Q08-AP7
NO5-Q08-AP7V1131
2 m (6.5 ft)
3-Pin Pico QD
PNP/LO
NO5-Q08-RP7
NO5-Q08-RP7V1131
2 m (6.5 ft)
3-Pin Pico QD
PNP/DO
Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix "W/30" to the cabled model number. For
example, NO5-Q08-AN7 W/30. Models with a QD connector require a mating cable. Performance based on 90% reflective white test
card.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Q08 Series Opposed-Mode Sensors
P/N 03558 Rev. E 8/19/2013
Page view 0
1 2 3 4

Summary of Contents

Page 1 - P/N 03558 Rev. E 8/19/2013

Low-profile infrared sensors in rugged metal housings• Miniature right-angle dc photoelectric sensors in rugged die-cast metal housings• Ultra-thin; o

Page 2 - Specifications

OverviewThis small, rugged infrared diffuse proximity mode sensor is contained within an 8-mm deep die-cast metal housing. It is totally self-containe

Page 3 - Hookup Diagrams

DimensionsCabled Models Quick-Disconnect Models Optical Center of Beam8.0 mm (0.32")20.0 mm (0.79")ø 3.40 mm (0.134")(2 Holes)#4 (M3) S

Page 4 - Accessories

Accessories3-Pin Snap/Pico-Style CordsetsModel Length Style Dimensions PinoutPKG3Z-2 2.00 m (6.56 ft) Straight28 mm max.(1.1")ø 10 mm max.(0.4&qu

Comments to this Manuals

No comments