Light screen for error-proofing of bin-picking operations
Compact package, available in 4 lengths to fit many sizes and configurations of existing
parts bins
Range up to 2 m (6.5 ft)
Two-component system (asynchronous emitter and receiver) needs no sync wire or con-
troller box.
Emitters and receivers sold separately or in pairs for easy ordering.
Two LEDs on each emitter and receiver indicate proper setup and system errors.
Clearly visible green job indicator lights mounted on either side of emitter and receiver
housings; the light can be remotely controlled to initiate user action with a solid ON or
blinking condition
Two frequency settings to prevent crosstalk in close-proximity, multiple-array installations
Easy DIP-switch selection of light/dark operate, solid/flashing job light, A/B frequency,
and gate polarity for activating the job light indicator.
Choose 2 m (6.5 ft) unterminated cable or 2 m (6.5 ft) cable with 4-pin Euro-style quick-
disconnect connector.
PNP or NPN receiver output, depending on model
12 to 30V dc operation
Minimum resolution 35 mm (1.4 in)
Wide beam pattern for easy alignment
Heavy-duty protective brackets available
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Models
Model
1
Description Array Length / # Beams Job Light Input
2
Receiver Output
PVA100N6 Emitter/Receiver Pair
100 mm (4 in) Long, 5
Beams
0V dc NPN (Sinking)PVA100N6E Emitter
PVA100N6R Receiver
PVA100P6 Emitter/Receiver Pair
+5 to 30V dc PNP (Sourcing)PVA100P6E Emitter
PVA100P6R Receiver
NOTE: Additional models on the next page.
1
Only cabled models (2 m (6.5 ft) unterminated integral cable) are listed. For 2 m (6.5 ft) pigtail with Euro-style Quick-disconnect fitting, add "Q" to the model number (for example,
PVA100N6Q).
2
See Configuration on page 5
PVA Pick-to-Light Array
P/N 52088_web
Rev. E
5/1/2013
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - PVA Pick-to-Light Array

Light screen for error-proofing of bin-picking operations• Compact package, available in 4 lengths to fit many sizes and configurations of existingpar

Page 2 - Overview

Models DIP Switch Access Light Protected Length (L) Used WithSMBPVA13 Yes No343.3 mm PVA300SMBPVA13A Yes YesSMBPVA13AB No YesSMBPVA16 Yes No418.2 mm P

Page 3 - Installation

Model3Description Array Length / # Beams Job Light Input4Receiver OutputPVA225N6 Emitter/Receiver Pair225 mm (9 in) Long, 5Beams0V dc NPN (Sinking)PVA

Page 4 - Mounting

InstallationMultiple sensor pairs located farther than the sensor's effective maximum range (approximately 2 m or 6.5 ft) from one another are un

Page 5 - Configuration

MountingThe wide beam pattern of PVA emitters and receivers simplifies their alignment. M4 stainlesssteel fasteners and two stainless steel brackets a

Page 6 - PVA Pick-to-Light Array

ConfigurationPVA configuration is accomplished using the DIP switches on the emitter and receiver as shown. When setting the DIP switches, use thesupp

Page 7 - Specifications

Status Indicators/TroubleshootingMODEStatus Indicator #1Status Indicator #2Figure 6. Status indicatorsEmitter Indicator Condition Description#1 OFF Fr

Page 8 - Dimensions

SpecificationsSupply Voltage and Current12 to 30V dc (10% max. ripple) at less than 62 mA forthe emitter and 50 mA for the receiver (exclusive ofload)

Page 9 - Accessories

DimensionsEmitter and Receiver MODEJob Lights15.0 mm(0.59")30.0 mm(1.18")Status Indicator 2Status Indicator 1Configuration Switch CoverCable

Page 10 - PVA Pick-to-Light Array

AccessoriesCordsets4-Pin Threaded M12/Euro-Style CordsetsModel Length Style Dimensions PinoutMQDC-406 1.83 m (6 ft)Straight44 Typ.ø 14.5M12 x 1 2341 1