.04" diameter coiled individual ber with bendable probe sensing end
Plastic Fiber Optic Assembly model PIP46UC
PIP46UC p/n 26087
SENSING RANGE: A function of the sensor. For further information, see the
data sheet packed with the sensor, or refer to the Banner product catalog.
TEMPERATURE EXTREMES: Temperatures below -30°C will cause
embrittlement of the plastic materials but will not cause transmission loss.
Temperatures above +70°C will cause both transmission loss and fiber
shrinkage.
REPEAT BENDING/FLEXING: Life expectancy of plastic fiber optic cable
is in excess of one million cycles at bend radii of no less than the minimum
(stated at right) and a bend of 90 degrees or less. Avoid stress at the point where
the cable enters the sensor ("control end") and at the sensing end tip. Coiled
plastic fiberoptic assemblies are recommended for any application requiring
reciprocating fiber motion.
OPERATING TEMPERATURE: -30 to +70°C (-20 to +158°F).
CHEMICAL RESISTANCE: The acrylic core of the monofilament opti-
cal fiber will be damaged by contact with acids, strong bases (alkalis) and
solvents. The polyethylene jacket will protect the fiber from most chemical
environments. However, materials may migrate through the jacket with long
term exposure. Samples of fiber optic material are available from Banner for
testing and evaluation.
MINIMUM BEND RADIUS OF PLASTIC FIBER: 1 inch (25 mm)
CONSTRUCTION:
OPTICAL FIBER: acrylic monofilament
PROTECTIVE JACKET: black polyethylene
BENDABLE PROBE END TIP: annealed T304 stainless steel
Printed in USA p/n 03438L4B
Model PIP46UC is an individual coiled plastic fiber optic assembly with a
3.5-inch (89 mm) long bendable probe type sensing end. Coiled plastic fibers
are especially suited to applications requiring repeated flexing (reciprocating
motion). This fiber is sold in pairs.
The PIP46UC operates in the opposed sensing mode. Sensing light is transmit-
ted or received through the end of the sensing probe (see drawing and photo).
Objects are detected when they break the light beam between two fiber ends.
Fiber core diameter is .04 inch.
The PIP46UC may be used with plastic fiber optic sensors from the following Banner sensor
families: D12, OMNI-BEAM, MAXI-BEAM, VALU-BEAM, Q45, Q19, PC44, MINI-BEAM,
and ECONO-BEAM. See page 2 for further information.
Description
Additional Specications
Fiber Cutting Information
PFC-1 Cutting Device
This Banner plastic fiber is designed to be cut by the customer to the length required
for the application. To facilitate cutting, a Banner model PFC-1 cutting device is
supplied with this fiber. Cut the fiber as follows:
1) Locate the "control end" of the fiber (the unfinished end). Determine the length
of fiber required for the application. Lift the top (blade) of the cutter to open the cutting
ports. Insert the control end of the fiber through one of the four large cutting ports on the
PFC-1 cutter so that the excess fiber protrudes from the back of the cutter.
2) Double-check the fiber length, and close the cutter until the fiber is cut.
3) Gently wipe the cut ends of the fiber with a clean, dry cloth to remove any contamination. Do not use solvents
or abrasives on any exposed optical fiber. Do not use a cutting port more than once. The blade may tend to dull after one cut.
"R" .5" (13 mm).
Use dowel, rod, or tubing
to form probe bend angle.
Bend gently and gradually.
Do not "kink" the probe.
The probe may not be bent
within 0.5 inches (13 mm) of either end.
Bending the
probe
Bendable probe sensing ends
Page view 0
1 2

Summary of Contents

Page 1 - PIP46UC p/n 26087

.04" diameter coiled individual ber with bendable probe sensing endPlastic Fiber Optic Assembly model PIP46UCPIP46UC p/n 26087SENSING RANGE:

Page 2

Fiber Installation InstructionsBanner Engineering Corp. 9714 Tenth Ave. No., Minneapolis, MN 55441 Telephone: (763) 544-3164 FAX:

Comments to this Manuals