Low-cost TEACH-mode sensors for use with plastic fiber optics
Models available with integral 2 m (6.5 ft)
cable or Pico-style quick-disconnect (QD)
connector; 9 m (30 ft) cables are also
available
Low-cost, 10 to 30V dc, self-contained, TEACH-mode sensors for use with all Banner
plastic fiber optics
Compact 11 mm-wide housing designed for DIN rail mounting; also mounts to other
surfaces using the supplied mounting bracket
Easy push-button TEACH-mode programming automatically adjusts sensitivity to opti-
mal setting
D11E sensors are designed for low-contrast sensing applications (sensitivity set to just
above the “dark” condition)
D11E2 series sensors set the switching point midway between the “dark” and “light”
conditions to ignore subtle changes, such as web flutter
Fast, 200 microsecond (0.2 millisecond) output response; a 40 millisecond output pulse
stretcher also may be programmed
Models available with NPN (sinking) or PNP (sourcing) output
Output may be programmed for either light operate (“LO”) or dark operate (“DO”)
Separate input allows remote programming by an external device, such as a switch or
a process controller
LED status indications for power ON, output state, received signal strength, and sens-
ing contrast
Models
Switching Threshold Set-
ting
Cable Output Type
Maximum Range (Diffuse mode performance
based on 90% reflectance white test card)
D11EN6FP
Just above the “dark” condi-
tion
2 m (6.5 ft)
NPN (sinking)
Range varies by sensing mode and fiber optics used:
PIT46U fibers, opposed mode: 180 mm (7.1")
1
PIT26U fibers, opposed mode: 50 mm (2.0")
PBT46U fiber, diffuse mode: 50 mm (2.0")
PBT26U fiber, diffuse mode: 10 mm (0.4")
D11EN6FPQ 4-pin Pico QD
D11EP6FP 2 m (6.5 ft)
PNP (sourcing)
D11EP6FPQ 4-pin Pico QD
D11E2N6FP
Midway between “dark” and
“light” conditions
2 m (6.5 ft)
NPN (sinking)
D11E2N6FPQ 4-pin Pico QD
D11E2P6FP 2 m (6.5 ft)
PNP (sourcing)
D11E2P6FPQ 4-pin Pico QD
Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix "W/30" to the cabled model number. For
example, D11EN6FP W/30. Models with a QD connector require a mating cable. (See Accessories).
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Specifications
Supply Voltage and Current
10 to 30V dc (10% maximum ripple) at less than 45
mA, exclusive of load
Required Fiber Optic Cable
PI or PB Series plastic fibers
1
Opposed-mode range may be extended using optional lenses (see catalog for available lenses).
D11 Expert Series
P/N 44279 Rev. C 8/6/2013
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - D11 Expert Series

Low-cost TEACH-mode sensors for use with plastic fiber opticsModels available with integral 2 m (6.5 ft)cable or Pico-style quick-disconnect (QD)conne

Page 2 - Run Mode

Supply Protection CircuitryProtected against reverse polarity and transient voltag-esOutput ConfigurationOne (SPST) NPN (sinking) or PNP (sourcing) op

Page 3 - TEACH Mode Programming

The Signal Strength indicator is Banner’s exclusive AID™ (Alignment Indicating Device 2). This feature simplifies accurate alignmentduring TEACH mode

Page 4 - Hookup Diagrams

Action Indicator StatusRed LED: Pulses to indicate relative received signal strengthTEACH Condition #1Present the first sensing condition to the senso

Page 5 - Dimensions

Sensors with NPN (Sinking) Outputs Sensors with PNP (Sourcing) Outputsbnbu−+bkwhLoad10-30V dcLoadRemote programmingswitch (normally open)Figure 3. Qui

Page 6 - Remote Programming

3. Slide the fiber gripper back down to lock.A fiber adaptor is included for use with 0.25 mm (0.01") or 0.5 mm (0.02") diameter fibers.Prog

Page 7

3. Enable or disable the 40- millisecond pulse stretcher.Connect a remote programming switch between thewhite wire and dc common (see Hookup Diagramso

Page 8 - D11 Expert Series

PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WAR-RANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE,