SI-HG80 Series Safety Interlock Switches encapsulated in a load-bearing hinge
Safety switch is integrated and encapsulated into a load-bearing hinge, providing a
high degree of protection from intentional defeat
Identical in appearance to non-switching blank hinge (see Accessories on page 6)
Switch components concealed inside the hinge are protected from mechanical impact,
providing superior performance to actuator-activated safety switches; rated IEC IP67
Hinge operates to a full 180° range of motion; safety switching point (guard-closed po-
sition) is adjustable over the full 0–180°operating range
Hinge can support an axial load of 750 N and more than 1,000 N in radial direction
When properly interfaced or used with an appropriate controller, two SI-HG80D..
switches can achieve safety category 4, per ISO 13849 (EN 954-1)
Robust zinc die-cast housing is corrosion resistant
Typical applications include:
Hinged covers and guards to machines
Hinged doors and gates in safety fencing systems
Modular aluminum framing
Inline QD Fitting Right-angle QD Fitting
Model QD Connection
Contact Configuration
(Closed State)
Contact Configuration
(Open State)
Switching Diagram
SI-HG80DQD Inline QD Fitting
13 24
134 2
1-2Safety
Operating
Angle
10°
10°
SI-HG80DQDR Right-angle QD Fitting
Note: Terminal #3 is non-safety.
Switching Diagram Key
Contacts: Open Closed Transition
Important Information Regarding the Use of Safety Switches
In the United States, the functions that Banner safety switches are intended to perform are regulated by the Occupational Safety and
Health Administration (OSHA). Whether or not any particular safety switch installation meets all applicable OSHA requirements depends
upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the safety switches are
applied, installed, wired, operated, and maintained.
Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. This in-
formation is found in the instruction manual packaged with each safety switch. In addition, we suggest that any questions regarding the
use or installation of safety switches be directed to the factory applications department at the telephone numbers or address shown
below.
Hinge Wing Safety Interlock Switches
P/N 046735 Rev. C 2/20/2013
0 046735 3
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - 0 046735 3

SI-HG80 Series Safety Interlock Switches encapsulated in a load-bearing hinge• Safety switch is integrated and encapsulated into a load-bearing hinge,

Page 2 - Mechanical Installation

Banner Engineering Corp. recommends that safety switches be applied according to the guidelines set forth in international (ISO/IEC)standards listed b

Page 3 - Electrical Installation

CAUTION:End Stops.Do not use the switch as an end stop. The operating angle of the switch must be limited by outer endstops.Setting the Switch PointCA

Page 4 - Periodic Checks

WARNING: Series Connection of Safety Interlock SwitchesMonitoring multiple guards with a series connection of safety interlock switches may result in

Page 5 - Specifications

CAUTION: Abuse of Module After FailureIf an internal fault has occurred and the Module will not reset, do not tap, strike, or otherwise attempt tocorr

Page 6 - Accessories

Accessories4-Pin Micro-Style CordsetsModel Length Style Dimensions PinoutMQEAC-406 1.83 m (6 ft)StraightM12 x 1ø14.5 mm(0.57")42 mm Typ.(1.65&quo