U-GAGE T30 Series Specifications (continued)
Construction
Environmental Rating Leakproof design is rated IEC IP67; NEMA 6P
Molded reinforced thermoplastic polyester housing
Vibration and
Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max., double amplitude
0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 ms duration, half sine wave.
Operating Conditions Temperature: -20° to +70° C (-4° to 158° F)
Maximum relative humidity: 100%
Application Notes Objects passing inside the specified near limit will produce a false response.
NOTE: For more information about out-of-range and signal loss response of the analog output, see page 5.
Connections 2 m (6.5') or 9 m (30') 5-conductor PVC-covered attached cable, or 5-pin Euro-style quick-disconnect
fitting (see page 9 for optional quick-disconnect cables)
U-GAGE T30 Series Performance Curves
U-GAGE T30 Effective Beam with Plate Target (Typical)
1-Meter Models
2-Meter Models
U-GAGE T30 Effective Beam with Rod Target (Typical)
1-Meter Models
2-Meter Models