SM-GA-5A (12-24V dc / 115V ac operation) and SM-HA-5A (12-24V dc / 230V ac operation)The user is responsible for satisfying all local, state, and nati
Multiple mats may be switched in series to one Safety Module. The Safety Module provides the redun-dant safety outputs required for creating a control
The Safety Module is powered by either a 12-24V dc supply at 4W or an ac supply (115V ac, model SM-GA-5A, or 230V ac, model SM-HA-5A) at 7VA. The sens
If Rm is: ThenLess than 150 ohms AND you are using an ACsupply or DC supply greater than 20V dcThe mat resistance is acceptable and the safety mat che
For Overvoltage Category III installations with applied voltages from 151V to 250V ac/dc applied to the output contact(s): the Safety Module may be us
1. Remove power to the machine control elements, if it is already connected.2.Apply force to the mat’s sensing area, using a test piece as outlined in
Category SpecificationAC-1: 250V ac, 5A; DC-1: 24V dc, 5AAC-15: 230V ac, 2A; DC-13: 24V dc, 4APower: 5 W (5 VA)Mechanical life: > 50,000,000 operat
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING