Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 Phone: 763.544.3164 • www.bannerengineering.com Email: sensors@bannerengineering.com
S18 Sensors dc-Voltage Series
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for
one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its
manufacture found to be defective at the time it is returned to the factory during the warranty
period. This warranty does not cover damage or liability for the improper application of
Banner products. This warranty is in lieu of any other warranty either expressed or implied.
P/N 116159
Supply Voltage and Current (exclusive of load current): 10 to 30V dc (10% max.
ripple); supply current (exclusive of load current):
Emitters, Non-Polarized Retro, Diffuse: 25 mA
Receivers: 20 mA
Polarized Retroreflective: 30 mA
Fixed-Field: 35 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current
sourcing) models
Light Operate: N.O. output conducts when sensor sees its own (or the
emitter’s) modulated light
Dark Operate: N.C. output conducts when the sensor sees dark; the N.C.
(normally closed) output may be wired as a normally open
marginal signal alarm output, depending upon hookup to power
supply (U.S. patent 5087838)
Output Rating
150 mA maximum (each) in standard hookup. When wired for alarm output, the
total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp @ 30V dc
ON-state saturation voltage: < 1V at 10 mA dc; < 1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short
circuit of outputs
Output Response Time
Opposed mode: 3 ms ON, 1.5 ms OFF
Retro, Fixed-Field and Diffuse: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this time.
Repeatability
Opposed mode: 375 µs
Retro, Fixed-Field and Diffuse: 750 µs
Repeatability and response are independent of signal strength.
Indicators
Two LEDs (Green and Yellow)
Green ON steady: power to sensor is ON
Green flashing: output is overloaded
Yellow ON steady: N.O. output is conducting
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
Construction
PBT polyester housing; polycarbonate (opposed mode) or acrylic lens
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m (6.5') or 9 m (30') attached cable, or 4-pin Euro-style quick-disconnect
fitting
Operating Conditions
Temperature: -40° to +70°C (-40° to +158°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration;
frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration 10G).
Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
Certifications
LISTED
R
Specifications
Quick-Disconnect (QD) Cables
Additional information on this product is immediately available online at www.bannerengineering.com/116159
View or download additional information, including excess gain curves, beam patterns and accessories.
For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.
Style Model Length Dimensions Pin-Out
4-pin
Euro-style
Straight
MQDC-406
MQDC-415
MQDC-430
2 m (6.5')
5 m (15')
9 m (30')
4-pin
Euro-style
Right-angle
MQDC-406RA
MQDC-415RA
MQDC-430RA
2 m (6.5')
5 m (15')
9 m (30')
38 mm max.
(1.5")
M12 x 1
ø 15 mm
(0.6")
38 mm max.
(1.5")
M12 x 1
ø 15 mm
(0.6")
44 mm max.
(1.7")
White Wire
Brown Wire
Black Wire
Blue Wire