QMT42 Series 400 mm Adjustable Field Sensors
Sensing Cutoff Point is Adjustable from 125 to 400 mm (5 to 16 in)
Printed in USA P/N 49211K7A
• Adjustable field technology allows direct detection of objects within a
defined sensing field, while completely ignoring reflective objects located
beyond the sensing field cutoff point
• Reliable
electronic
adjustment* of sensing field cutoff point from 125 to
400 mm; no mechanical adjustments to worry about
• Compact, rugged, low cost self-contained sensors in metal die cast
housings
• Epoxy-encapsulated circuitry; leakproof IP67 (NEMA 6) construction for
reliable sensing in harsh environments
• Outstanding electrical noise immunity
• Dual LED system indicates sensor performance
• Choice of integral cable or quick disconnect connector
* Patent Pending
Features
QMT42 Adjustable Field Mode
QMT42VN6AFV400
QMT42VN6AFV400Q
25 mm
(1 in) to
Cutoff
point
2 m (6.5 ft)
4-pin Euro QD
10-30V dc
NPN
Models Range Cable
Supply
Voltage
Output
Type
Cutoff Point Deviation
QMT42VP6AFV400
QMT42VP6AFV400Q
2 m (6.5 ft)
4-pin Euro QD
PNP
0
-8
-10
-6
-4
-2
0
+2
+4
+6
+8
+10
75 mm
(1 in)
150 mm
(2 in)
225 mm
(3 in)
300 mm
(4 in)
Cutoff Point Variation Relative to 90% Reflectance White Test Card
Percent
Deviation
375 mm
(5 in)
450 mm
(6 in)
18% Gray Color Sensitivity
6 % Black Color Sensitivity
Visible Red, 680 nm
125 to
400 mm
(5 to
16 in)
Cutoff
Point
Interpretation of Performance Curves
The percentage of deviation indicates a change in the cutoff point for either 18% gray or 6% black targets, relative to
the cutoff point set for a 90% reflective white test card.
As an example, the cutoff point decreases 10% for a 6% reflectance black target when the cutoff point is adjusted for
400 millimeters (16 inches) using a 90% reflectance white test card. In other words, the cutoff point for the black
target is 360 millimeters (14 inches) for this setting.
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - QMT42 Adjustable Field Mode

QMT42 Series 400 mm Adjustable Field SensorsSensing Cutoff Point is Adjustable from 125 to 400 mm (5 to 16 in)Printed in USA P/N 49211K7A• Adjustable

Page 2 - Sensing Axis

QMT42 Series 400 mm Adjustable Field Sensorspage 2 Banner Engineering CorporationAdjustable Field Sensing - Theory of OperationThe receiver element of

Page 3 - Product Specifications

QMT42 Series 400 mm Adjustable Field SensorsBanner Engineering Corporation page 3Product SpecificationsSensing BeamAdjustments All models have a 15-tu

Page 4 - Dimensions

QMT42 Series 400 mm Adjustable Field Sensorspage 4 Banner Engineering CorporationSensors with NPN (Sinking) Outputs Sensors with PNP (Sourcing) Output

Page 5 - Mounting Brackets

QMT42 Series 400 mm Adjustable Field SensorsBanner Engineering Corporation page 5Quick Disconnect (QD) CablesM12 x 1ø15 mm(0.6 in)44 mm max.(1.7 in)Th

Page 6

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications) (612) 544-3573WARRANTY: Bann