Model Type Housing Material
SP12SEL
SP12PEL
SP12SRL
SP12PRL
Emitter
Emitter
Receiver
Receiver
Stainless steel
VALOX
®
Stainless steel
VALOX
®
NOTE: Models with 30-foot attached cable are available (contact factory
for information). 2- and 3-conductor 50- and 100-foot extension cables
(without connectors) are also available. For 2-conductor (emitter) cable:
order model EC12E-50 (50') or model EC12E-100 (100'). For 3-conductor
(receiver) cable: order model EC12R-50 (50') or model EC12R-100 (100').
VALOX
®
is a registered trademark of General Electric Co.
10
0
DISTANCE
100
100
0
1 FT
SP12 Series
opposed mode
emitters and
receivers
10 FT 100 FT 1000FT
E
X
C
E
S
S
G
A
I
N
I
15ms
response
1.5ms
response
Beam PatternExcess Gain Curve
400
0
I
N
C
H
E
S
OPPOSED DISTANCE--FEET
80 120 160 200
20
40
60
20
40
60
SP12 Series emitters
and receivers
1.5ms response
15ms response
Banner SP12 Series sensors are a family of powerful, modulated, totally-
encapsulated opposed mode remote sensor pairs in compact, threaded-
barrel type housings. They are the ideal choice for applications that
require high excess gain together with small size in difficult sensing
environments. SP12 Series sensors are especially effective at penetrating
heavy contaminants when used at close range.
The preamplified design of these sensors results in exceptional noise
immunity. Signals carried along remote receiver cables are often subject
to interference (from electrical noise sources) that can be as strong as (or
stronger than) the desired light signal. The severity of this problem often
worsens with increasing sensor cable length. SP12 Series receivers
contain a preamplifier that immediately boosts the received light signal to
a high level before sending it down the cable to the rest of the sensing
system.
SP12 Series sensors are designed for use with the Banner CD Series
MAXI-AMP™ modules. CD Series modules provide sensor power,
additional amplification, a choice of several programmable timing logic
functions (CD5 models), and output circuitry for interfacing to a load.
They also allow two different programmable sensor modulation frequen-
cies, making it possible to use multiple high-powered sensor pairs in close
proximity to each other without optical crosstalk. CD Series modules are
available for a wide range of supply voltages. Each CD module powers
one SP12 emitter/receiver pair. See data sheet 03570 for information.
SP12 sensors are rated NEMA 6P (IEC IP67) for use in wet locations.
There is a choice of either VALOX
®
or stainless steel housing style (see
table, below). Positive sealing at both ends of the sensors, with no exposed
epoxy interfaces, eliminates all leak paths (including capillary leakage).
Electronics are fully encapsulated for maximum resistance to mechanical
shock and vibration. Lenses are acrylic, and quad-ring sealed. These
sensors may be used with watertight, thread-on apertures to create very
narrow, very powerful effective beams (see page 2).
A 1/2" clearance hole is required for mounting. Alternatively, the Banner
model SMB12MM mounting bracket may be used (page 2). SP12 Series
sensors are supplied with 6-1/2 feet of PVC-covered attached cable, or
with 4-pin eurofast™ QD fittings. Options for models with attached cable
are summarized below. See page 4 for QD models. The maximum
recommended emitter or receiver cable length is 100 feet (each). See
pages 2 and 3 for wiring and hookup information.
Dimension Drawing
(QD models page 4)
Specifications, SP12 Sensors
SP12 Series sensors (foreground) shown with MAXI-AMP™
CD Series amplifier and logic
modules (data sheet P/N 03570).
Models are also available with QD connectors (page 4).
for use with MAXI-AMP CD Series Modules
SUPPLY VOLTAGE: sensors are powered from a Banner CD Series
MAXI-AMP™ module.
RANGE: up to 200 feet in opposed mode (see gain curve, above).
RESPONSE SPEED: selectable for 1.5 or 15 milliseconds; a function
of the MAXI-AMP CD Series module.
LIGHT BEAM: infrared LED, 880nm. Effective beam diameter: 3/8".
CONSTRUCTION: NEMA 6P.
12mm diameter tubular threaded VALOX
®
or stainless steel housing;
positive sealing at both ends, quad-ring sealed acrylic lens. Electron-
ics fully epoxy-encapsulated. Two jam nuts are provided: VALOX
®
for VALOX
®
units; stainless steel for stainless steel units. Mounting
requires 1/2" diameter clearance hole.
OPERATING TEMPERATURE: -40 to +70°C (-40 to +158°F).
CABLE: sensors are supplied with 6-1/2 feet of PVC-covered 2- or 3-
conductor cable. Models with QD fittings are available (page 4).
SP12 Series Barrel Sensors (cabled models)
Printed in USA P/N 34466
Leakproof NEMA 6P threaded-barrel opposed mode
remote sensor pairs; VALOX
®
or stainless steel housing
Compact and powerful: 1/2" (12mm) in diameter by 2"
long; 200-foot sensing range. Apertures are available.
Special preamplified circuit design for noise immunity
equal to that of self-contained sensors
SP12 Series High Power Modulated Remote Barrel Sensors
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Specifications, SP12 Sensors

Model Type Housing MaterialSP12SELSP12PELSP12SRLSP12PRLEmitterEmitterReceiverReceiverStainless steelVALOX®Stainless steelVALOX®NOTE: Models with 30-fo

Page 2

!WARNING These photoelectric sensing devices do NOT include the self-checking redundant circuitry necessary to allowtheir use in personnel safety app

Page 3 - SP12 Series Sensors

3) Power for External Devices (all models)External 10 to 30V dc devices such as self-contained sensors may be connected be-tween terminals #3 (+) and

Page 4

SP12 Series SensorsBanner Engineering Corp. 9714 Tenth Ave. No. Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications): (612

Comments to this Manuals

No comments